Generated by All in One SEO v4.9.2, this is an llms.txt file, used by LLMs to index the site. # Asplundh Engineering Services Powering the Future ## Sitemaps - [XML Sitemap](https://kupperengineering.com/sitemap.xml): Contains all public & indexable URLs for this website. ## Pages - [Home](https://kupperengineering.com/) - Asplundh Engineering Kupper Delivering Peace of Mind Ambler RNG Solar Controls - [Careers](https://kupperengineering.com/careers/) - Asplundh Engineering Services is always seeking highly skilled, self-motivated, creative professionals to join its consulting engineering team. We are seeking interns, graduate engineers, professional engineers, CAD operators, and designers/engineers for mechanical, electrical, plumbing, and fire protection projects. If you are interested in providing high-end engineering consulting design, construction, maintenance, and project management services, AES may - [Privacy Policy](https://kupperengineering.com/privacypolicy/) - PRIVACY POLICY Last Updated July 19, 2023 INTRODUCTION Asplundh Engineering Services, LLC (“we” or “us” or “our”) respects the privacy of our customers and users (“user” or “you”). We are committed to ensuring that your privacy is protected. Should we ask you to provide certain information by which you can be identified when using this - [Privacy Policy CPRA](https://kupperengineering.com/privacypolicy-ccpa/) - ASPLUNDH ENGINEERING SERVICES CCPA PRIVACY POLICY FORWORK-RELATED INDIVIDUALS WHO ARE RESIDENTS OF CALIFORNIA PURPOSE AND INTENT Asplundh Engineering Services, LLC (the “Company”) is committed to protecting the privacy and security of the personal information of individuals who inquire about employment with the Company, our job applicants, employees and their emergency contacts and beneficiaries, independent contractors, - [Leadership Team](https://kupperengineering.com/about-us/leadershipteam/) - Senior Vice President Scott Kupper, PE Vice President of Operations Karl Miller Vice President of Controls and Maintenance Craig Rosenberger, PE Vice President of Engineering Philip Parise, PE Director Controls and Maintenance Adam Brugnoli Controller Stephen DiBello, CPA Engineering Manager Doug Wilford, PE Design Manager Frank Herb Principal Electrical Engineer Drew Carré, PE Principal Systems - [About Us](https://kupperengineering.com/about-us/) - About Us Passionate about our work. Innovative. Continuously evolving. History About Us Meet the Team Leads - [History](https://kupperengineering.com/history/) - [Utilities Engineering](https://kupperengineering.com/services/utility-communications/) - UTILITIES ENGINEERING Asplundh Engineering Services provides electrical engineering design involving power systems, emergency power, and electrical distribution. Our experience includes medium and high voltage switchgear systems, power factor correction, medium voltage overhead line design, radio transfer trip systems, and grounding systems. Interconnection AES conducts onsite surveys, preparing single-line and three-line diagrams for submission to permitting - [Systems Integration](https://kupperengineering.com/services/system-integration/) - Systems Integration Asplundh Engineering Services's SCADA (Supervisory Control and Data Acquisition) systems bring together all individual sub-systems under one centralized system allowing greater control and advanced analytics of all data points. Asplundh Engineering Services is an authorized dealer for these integration platform software packages: SCADA SCADA systems are the centralized systems that monitor and control - [Renewable Energy](https://kupperengineering.com/services/renewable-energy/) - Renewable Energy The need to control energy costs while displaying a responsible corporate sustainability posture is important to our clients. Our renewable energy experience encompasses all spectrums of cogeneration projects from coast to coast, including landfill/biogas to energy, solar, and wind. As costs and regulations rise, our team is here to help you weigh options - [Protective Relays and Studies](https://kupperengineering.com/services/protective-relays-studies/) - Protective Relays and Studies Asplundh Engineering Services has vast experience in testing, commissioning, and modifying electrical, mechanical, HVAC, and IT systems for clients whose infrastructure must not fail. Our work in Fortune 500 data centers, world renowned hospitals, and major sports stadiums speaks volumes in regard to our experience and the trust our clients afford - [Procurement/EPC](https://kupperengineering.com/services/procurementepc/) - ProcurementEPC From initial concept through commissioning and turnover, Asplundh Engineering Services concentrates all of our efforts with one shared goal in mind – the final delivery and success of the project. Clients with large, complex energy generation and system integration projects come to us for our comprehensive engineering, procurement, and construction (EPC) services when they need - [Mission Critical Systems](https://kupperengineering.com/services/mission-critical-systems/) - Mission Critical Systems The data center is no longer static. Age old engineering principals are coming under greater scrutiny because the logic and principals no longer apply to the new fluidity of modern devices. Understanding your options and how they impact redundancy and cost are critical to data center design, build, and ongoing operation. At - [Commercial & Industrial (C&I)](https://kupperengineering.com/services/commercial-industrial-ci/) - Commercial & Industrial Asplundh Engineering Services delivers complete MEP engineering services that are timely and accurate for office buildings, tenant fit-outs, and upgrades. Our clients range from commercial giants to schools, government buildings, and even cogeneration facilities. With AES, you get immediate access to world class professionals who take you step-by-step through every phase of - [Services](https://kupperengineering.com/services/) - Asplundh Engineering Services has a proven track record of delivering energy efficient solutions and innovative energy engineering projects. Our system integration and SCADA services bring together all individual subsystems under one centralized system allowing greater control and advanced analytics of all data points. Renewable Energy Landfill Gas and Biogas/Biomass Conversion to Energy Solar and Wind - [Contact Us](https://kupperengineering.com/contact-us/) - Email: info@kupperengineering.com Asplundh Engineering Services, LLC300 Brookside AvenueBuilding 14Ambler, PA 19002 Phone: 215.884.5970Fax: 215.884.5973 - [Arc Flash Hazard Analysis](https://kupperengineering.com/arc-flash-hazard-analysis/) - Arc Flash Dangers An arc flash is a rapid release of electricity – typically the result of a short circuit fault – that arcs through the air between two conductors, discharging dangerous amounts of energy. The arc can produce intense light, with temperatures as high as 35,000 °F, blasting molten metal, pressure and sound waves, - [Projects](https://kupperengineering.com/projects/) - [My Tickets](https://kupperengineering.com/my-tickets/) - [tickets] - [Submit Ticket](https://kupperengineering.com/submit-ticket/) - [ticket-submit] - [Service and Maintenance Center](https://kupperengineering.com/services/service-and-maintenance-center/) - With a dedicated phone number, email, and 24/7 support, our Service and Maintenance Center provides the following range of services and benefits to assist you and your facility. – Preventive maintenance to help avoid system failures– Emergency response services to reduce downtime– Easy scheduling and quick turnaround for remote and onsite service and maintenance Support - [News](https://kupperengineering.com/news/) ## Projects - [450MW Hydroelectric Power Plant](https://kupperengineering.com/project/450mw-hydroelectric-power-plant/) - Kupper provided system integration services for a utility RTU that included design, assembly, programming, and testing. Kupper provided coordination of data points, communication diagrams, RTU installation diagrams, onsite startup, and verification. For consistency in hardware within the site, the Allen Bradley ControlLogix PLC hardware was provided to concentrate all digital and analog signals. - [Greentree Landfill RNG Facility](https://kupperengineering.com/project/greentree-landfill-rng-facility/) - Kupper Engineering provided full electrical engineering and mechanical engineering services, as well as a complete control system for the new hydrogen sulfide (H2S) removal system and ancillary equipment at the Greentree Landfill’s 4000 scfm renewable natural gas (RNG) facility. Our team procured the motor control center and provided coordination of implementing the new equipment with - [SCADA Panel for Water Treatment Facility](https://kupperengineering.com/project/scada-panel-for-water-treatment-facility/) - Kupper Engineering designed and built several control panels for a water treatment plant in Lancaster County, PA. This included a wastewater local control panel, as well as two panels at each remote well site (SCADA enclosure and VFD enclosure), a central control panel, and a remote monitoring panel enclosure for the facility’s water tower. - [Pharmaceutical Company Headquarters Fit Out](https://kupperengineering.com/project/pharmaceutical-company-headquarters-fit-out-4/) - Kupper provided MEP design services and construction administration services for the top floor of this 20,000 square foot 4-story building. This included schematic design, design development, and construction documentation and permit drawings. Photo Credit: © Jeffrey Totaro, 2018. - [23.5 MW Solar Project for Six Flags Great Adventure](https://kupperengineering.com/project/23-5-mw-solar-project-for-six-flags-great-adventure/) - Kupper Engineering designed a 38kV substation fenced yard and provided utility interconnection documentation for this utility-grid connected project at the Six Flags Great Adventure theme park in Jackson, NJ. Our team provided telecommunications coordination and performed a short circuit analysis, coordination, and arc flash study. We designed the 23.5 MW DC/17 MW AC string inverter-based - [LCSWMA Landfill and Waste-to-Energy Facilities](https://kupperengineering.com/project/lcswma-landfill-and-waste-to-energy-facilities/) - Our SCADA system provides effluent water monitoring and weather monitoring for the Lancaster County Solid Waste Management Authority’s (LCSWMA) Creswell Landfill site. Our controls and automation team also provides full systems control monitoring services to LCSWMA’s adjacent Frey Farm Landfill. In addition, we perform high precision monitoring and fee calculations for the steam and process - [3.2MW Biogas Digester Plant](https://kupperengineering.com/project/3-2mw-biogas-digester-plant/) - Kupper provided professional electrical engineering low voltage and medium voltage design services for a 3.2MW biogas digester plant with an interconnection application to National Grid Rhode Island at 23kV. Services included coordination with National Grid Engineering and Standards. Kupper also performed a short circuit coordination study to include relay programming, with arc flash hazard analysis, - [3MW Landfill Gas-to-Energy Project](https://kupperengineering.com/project/3mw-landfill-gas-to-energy-project/) - Kupper provided full design of new station control and protection panels for the new connection to the Los Angeles Department of Water and Power (LADWP). We also designed a new SCADA system for the entire power plant, including the existing connection to Southern California Edison. In addition, we supplied all medium voltage equipment, such as - [Digester Gas Fuel Cell – Waste Water Treatment Plant](https://kupperengineering.com/project/digester-gas-fuel-cell-waste-water-treatment-plant/) - Kupper provided full electrical design for a new digester gas conditioning system for the City of San Diego’s Waste Water Treatment Plant. The design included a tie to the existing 4.16kV system, a fuel cell, a new step up transformer, parasitic loads, control wiring, a coordination study, and ground grid design. - [2.52MW Landfill Gas-to-Energy Project](https://kupperengineering.com/project/2-52mw-landfill-gas-to-energy-project/) - We provided full electrical design of a 2.52MW landfill gas to energy facility with the utility interface at 34.5kV. This was a retrofit of an existing legacy plant with new engines and controls. The design included associated paralleling switchgear, electrical design for parasitic loads, control wiring, ground grid design, and tie-in to the base fire - [High BTU Plant Conversion from LFG to RNG](https://kupperengineering.com/project/high-btu-plant-conversion-from-lfg-to-rng-2/) - Kupper Engineering provided electrical engineering design services for a new high BTU plant to convert landfill gas to renewable natural gas. Kupper drafted single line diagrams for all systems, including medium voltage (15kV service, 5kV motors). Our team also provided a major electrical equipment layout plan, and electrical design, which included miscellaneous power to skids, - [10MW DC/8MW AC Solar Farm Project](https://kupperengineering.com/project/10mw-dc8mw-ac-solar-farm-project/) - Kupper provided system integration services for a National Grid RTU at a solar facility. This included detailed design and assembly of the RTU and the remote router enclosure, interconnection drawings for the connected equipment, configuring the communications settings on the customer metering, and testing services with National Grid during startup. - [Industrial Manufacturing Facility](https://kupperengineering.com/project/industrial-manufacturing-facility/) - Kupper programmed an Allen Bradley CompactLogix PLC using the latest version and firmware available. The programming was structured in design, making use of subroutines, and annotated to create a program that was easily interpreted and maintained. Kupper supplied programming and labor of the following: One hundred alarms, digital and analog Three PID control loops Main - [Pharmaceutical Company Office Fit Out](https://kupperengineering.com/project/pharmaceutical-company-office-fit-out/) - For the local offices of a pharmaceutical firm, Kupper provided MEP design services and construction administration services for the top floor of a 20,000 square foot 4-story building. - [Pharmaceutical Company Headquarters Fit Out](https://kupperengineering.com/project/pharmaceutical-company-headquarters-fit-out/) - Kupper provided MEP design services and construction administration services for the top floor of this 20,000 square foot 4-story building. This included schematic design, design development, construction documentation, and permit drawings. - [Pharmaceutical Company Headquarters Fit Out](https://kupperengineering.com/project/pharmaceutical-company-headquarters-fit-out-3/) - Kupper provided MEP design services and construction administration services for the top floor of this 20,000 square foot 4-story building. This included schematic design, design development, and construction documentation and permit drawings. Photo Credit: © Jeffrey Totaro, 2018. - [Medical Center](https://kupperengineering.com/project/medical-center/) - It was determined that the existing glycol cooler tower was installed in such a way that it could not be shut down for maintenance without a complete outage to the DC cooling. This regional medical center requested that Kupper provide the design for a redundant cooling tower dedicated to the glycol cooling loop serving the - [International Furniture Retailer Tier III Data Center Upgrade](https://kupperengineering.com/project/international-furniture-retailer-tier-iii-data-center-upgrade/) - The scope of this project involved the design of the “B” side UPS distribution to provide a maximum capacity of 180kW of redundant UPS power. We performed a site survey to identify existing conditions, locate and detail equipment locations, and survey conduit runs. Our team provided single line diagrams and floor plans for installation of - [Pharmaceutical Company Headquarters Tenant Fit Out](https://kupperengineering.com/project/pharmaceutical-company-headquarters-tenant-fit-out/) - Kupper provided MEP design services and construction administration services for the top floor of this 20,000 square foot 4-story building. This included schematic design, design development, and construction documentation and permit drawings. Photo Credit: © Jeffrey Totaro, 2018. - [3.4 MW Biogas Food Waste Recycling Plant](https://kupperengineering.com/project/3-3-mw-biogas-food-waste-recycling-plant/) - Kupper Engineering provided electrical engineering services for a 3.4 MW biogas food waste recycling plant, which diverts 100,000 tons of organic material from landfills to produce approximately 29,000 megawatt-hours of steady state power on an annual basis. Services included 13.2kV medium voltage interconnection design and PSE&G documentation, as well as electrical engineering of the medium - [Franklin County Jail Energy Conservation Project](https://kupperengineering.com/project/franklin-county-jail-energy-conservation-project/) - Kupper Engineering provided electrical and mechanical engineering, and systems integration services, for several energy conservation measures at the Franklin County Jail and House of Correction in Greenfield, MA. These conservation measures included providing and specifying energy efficient boilers, installing VFDs on an existing chiller and new AHUs, as well as providing a new shower control - [1.75 MW Solar & Battery Storage System](https://kupperengineering.com/project/1-75-mw-solar-battery-storage-system/) - Kupper Engineering provided electrical engineering services to design the interconnection of a combined 1.75 MW solar array and battery storage project on the campus of Chesapeake College. The system was connected to the existing campus to provide back up power in the event of a Delmarva Power & Light outage. Kupper also provided system integration - [Spring Creek Towers - Capital Improvements Project](https://kupperengineering.com/project/spring-creek-towers-capital-improvement-project/) - Kupper Engineering provided engineering services to identify, design, and implement capital improvements for Spring Creek Towers, a Brooklyn, NY-based housing development. This involved improvements to the housing community's power generation and distribution in order to provide its residents with more reliable, sustainable, and efficient energy. Our project involvement included the following: Procurement of new 5kV - [7 MW Solar Net Metered System](https://kupperengineering.com/project/7-mw-solar-net-metered-system/) - Kupper Engineering provided electrical engineering, design, and controls services, as well as equipment procurement for a 7 MW ground mounted solar project in central New Jersey. Controls services included the system integration for the FirstEnergy RTU and custom meter panels. - [Water Treatment Plant SCADA System](https://kupperengineering.com/project/water-treatment-plant-scada-system/) - Kupper Engineering designed and built several control panels for a water treatment plant in Lancaster County, PA. This included a wastewater local control panel, as well as two panels at each remote well site (SCADA enclosure and VFD enclosure), a central control panel, and a remote monitoring panel enclosure for the facility’s water tower. - [Premier Orthopedics Ambulatory Surgery Center](https://kupperengineering.com/project/premier-orthopedics-ambulatory-surgery-center/) - We provided mechanical, electrical, plumbing, and fire protection engineering and design services for this 21,000 square foot ground-up surgery center building in Collegeville, PA. The scope of work included core and shell design and tenant improvements for the second floor. The tenant improvement portion of the project included the design of an x-ray area, examination - [3.3 MW DC Solar Garden Project](https://kupperengineering.com/project/3-3-mw-dc-solar-garden-project/) - Kupper Engineering provided full electrical engineering design services for this 3.3 MW DC ground mount solar garden project in Burrillville, RI. The project, acquired and operated by Nautilus Solar Energy, represents the state’s first operational community solar project under the Rhode Island Community Remote Net Metering Pilot Program. Kupper's services included medium voltage and low - [Swarthmore College's Michael Mullan Tennis Center](https://kupperengineering.com/project/swarthmore-colleges-michael-mullan-tennis-center/) - Kupper Engineering provided mechanical, electrical, and plumbing engineering services for Swarthmore College’s Michael Mullan Tennis Center on the college’s campus in Swarthmore, PA. Our team performed HVAC load calculations for the new golf room, fitness area, and physical therapy area within the Center, and designed a new variable refrigerant flow heating and cooling system with - [Six Flags Great Adventure's 23.5 MW DC Solar PV System](https://kupperengineering.com/project/six-flags-great-adventures-23-5-mw-dc-solar-pv-system/) - Kupper Engineering designed a 38kV substation fenced yard and provided utility interconnection documentation for this utility-grid connected project at the Six Flags Great Adventure theme park in Jackson, N.J. Our team provided telecommunications coordination and a short circuit analysis, coordination, and arc flash study. We designed the 23.5 MW DC / 17 MW AC string - [3 MW DC Solar PV System](https://kupperengineering.com/project/3mw-dc-solar-pv-system/) - We provided complete electrical design of both AC and DC systems, including all coordination with PSE&G, the local utility. This non-tracking, fixed ground mount array featured a 600VDC design utilizing five (5) central inverters and two (2) different types of modules. We also provided the accelerated procurement of 5kV circuit breaker lineup, assisted with additional - [Ten (10) 6.6 MW Rooftop Solar Malls](https://kupperengineering.com/project/ten-10-6-6mw-rooftop-solar-malls/) - We performed full AC and DC electrical engineering design services, including PV layout, behind the meter interconnection, AC distribution, and monitoring and controls for the rooftop PV systems on 10 large scale malls throughout the U.S., totaling approximately 6.6 MW of solar energy. These projects spanned eight different states and eight different utility and city/township - [3.5 MW AC Solar System for a Retailer’s Fulfillment Center](https://kupperengineering.com/project/3-5mw-ac-solar-system-for-a-retailers-fulfillment-center/) - Located within PPL service territory, this 3.5 MW AC solar photovoltaic system was installed behind the meter on a 12.47kV bus, and consisted of three (3) separate inverter power stations, two (2) at 1 MW and one (1) at 1.5 MW. We provided professional engineering services for utility coordination, switchgear design assistance, and AC/DC design - [2.5 MW Wind Energy for a College](https://kupperengineering.com/project/2-5mw-wind-energy-for-a-college/) - This project entailed the full electrical design of a 2.5 MW wind energy facility with the utility interface at 12.47kV. The energy is sold directly back to the local utility, Alliant Energy. Clipper Wind, whose manufacturing plant in Cedar Rapids is located adjacent to a college, teamed up with the college to provide the students - [3.2 MW Wind Energy Farm for a Landfill](https://kupperengineering.com/project/3-2mw-wind-energy-farm-for-a-landfill/) - This project entailed the full electrical design of a 3.2 MW wind energy facility with the utility interface at 13.2kV. The energy is sold to local manufacturing firms and is net metered through their facilities with excess sold back directly to the grid (PJM) using an ARCOM director. Our design included ground resistors, 15kV switchgear, - [Franklin County Jail Energy Conservation Project](https://kupperengineering.com/project/franklin-county-jail-energy-conservation-project-2/) - Our team provided electrical and mechanical engineering, and systems integration services, for several energy conservation measures at the Franklin County Jail and House of Correction in Greenfield, MA. These conservation measures included providing and specifying energy efficient boilers, installing VFDs on an existing chiller and new AHUs, as well as providing a new shower control - [10 MW DC/8 MW AC Solar Farm Project](https://kupperengineering.com/project/10mw-dc8mw-ac-solar-farm-project-2/) - Located within Jersey Central Power & Light’s (JCP&L) service territory at 34.5kV, this project involved providing the electrical design for a 10 MW DC/8 MW AC interconnection at a solar farm in Flemington, NJ, and handling all coordination with PJM and JCP&L. Our team performed a short circuit and coordination study with arc flash hazard - [5.5 MW DC Net-Metered Solar Project](https://kupperengineering.com/project/5-5-mw-dc-net-metered-solar-project/) - Kupper Engineering provided full electrical engineering design services, utility coordination, and system integration/SCADA monitoring services for this 5.5 MW DC net-metered solar project supplying power to Ardagh Group, a glass manufacturing facility in Bridgeton, N.J. Key project features: 15,930 PV modules supported by 1,283 racking posts 61 pieces of electrical equipment 60 miles of wire installed 20 - [H2S Scrubber Control System for a Landfill Facility](https://kupperengineering.com/project/h2s-scrubber-control-system-for-a-landfill-facility/) - We provided system integrations services for the H2S control system at a county landfill in Boise, ID to remove H2S from the landfill gas stream. Our services included electrical engineering design services, and coordination and design of communications connections for SCADA system integration. Our team provided all hardware and programming in the PLC panel to - [Custom Meter Panel for a Solar Site](https://kupperengineering.com/project/custom-meter-panel-for-a-solar-site/) - We provided all system integration services, including the design and assembly of the custom protective relay panel for a rooftop solar project consisting of 31,000 solar panels at a Los Angeles mail processing distribution center. We designed the 3-line interconnections from the meter to the 38kV switchgear, provided panel installation drawings, packaged the panel for - [12MW Landfill Gas Cogeneration Project](https://kupperengineering.com/project/12mw-landfill-gas-cogeneration-project/) - Preliminary engineering design and PPL utility interconnect applications were provided for two (2) 5.7MW solar turbines at 12470V repowering of the industrial manufacturing site. Two (2) additional heat recovery steam generators were installed to produce steam from the turbines’ heat and send the steam to existing boilers at the facility. We also completed the interconnection - [2MW CHP for Beverage Production Facility](https://kupperengineering.com/project/2mw-chp-for-beverage-production-facility/) - We provided electrical engineering design services for the installation of a 2 megawatt natural gas-fired combined heat and power (CHP) generator to help the facility better manage its energy needs. This included a new utility and gas service and new RTUs. As a result, the plant's electricity usage decreased by 80%, and its natural gas - [Technology Company Short Circuit and Coordination Study with Arc Flash Hazard Analysis](https://kupperengineering.com/project/technology-company-short-circuit-and-coordination-study-with-arc-flash-hazard-analysis/) - We provided a short circuit and coordination study with an arc flash hazard analysis study for a technology company’s campus. The site included the following: Building 1: 80,000 square feet, (4) floors Building 2: 60,000 square feet, (3) floors Building 3: 60,000 square feet, (3) floors Building 4: 80,000 square feet, (4) floors (data center - [Short Circuit and Coordination Study with Arc Flash Hazard Analysis for a National Video and Ecommerce Retailer](https://kupperengineering.com/project/short-circuit-and-coordination-study-with-arc-flash-hazard-analysis-for-a-national-video-and-ecommerce-retailer/) - We provided a short circuit study review and update of the entire electrical distribution system, including incoming utility service, primary switchgear, transformers, emergency generators, and all associated 480V and 208V distribution. Our team performed a review and update of the protective device coordination study of the electrical system and associated feeders to the nearest downstream - [6.3MW Solar Site for a Medical Center](https://kupperengineering.com/project/6-3mw-solar-site-for-a-medical-center/) - We provided system integration services for the FirstEnergy utility RTU system and programming per FirstEnergy standards. The scope of work included design, assembly, programming, and testing, as well as a short circuit and coordination study with arc flash hazard analysis from the utility intertie to the inverter input protective device. We also provided relay settings - [Dairy Digester RNG Facility](https://kupperengineering.com/project/dairy-digester-rng-facility/) - Jerome, ID We provided electrical and controls system engineering design services for the installation of a 1400 SCFM digester gas to a renewable natural gas (RNG) facility. This included engineering design services for development of electrical single line diagrams with major electrical loads and equipment, specification of major electrical equipment, design of electrical equipment layout - [RNG Pipeline and Compressor Station](https://kupperengineering.com/project/rng-pipeline-and-compressor-station/) - Northern California We provided engineering services to design a booster compressor station and pipeline to deliver renewable natural gas at a facility in northern California. We utilized the existing distribution to feed additional equipment. Our team initially provided full electrical design services for this facility's digester gas project in 2011. This included a new digester - [Dairy Digester RNG Facility](https://kupperengineering.com/project/dairy-digester-rng-facility-2/) - Cactus, TX We provided electrical and controls system engineering design services for the installation of 1450 SCFM digester gas to a renewable natural gas (RNG) facility. Our team also provided coordination of new medium voltage interconnection with the utility. Design documents included PFDs, specifications for procurement of major equipment and materials, electrical single line diagrams, - [Wastewater Treatment Plant Digester Gas Fuel Cell](https://kupperengineering.com/project/wastewater-treatment-plant-digester-gas-fuel-cell/) - Southern California We provided electrical engineering design services for a wastewater treatment plant, which occupies a 40-acre site and treats approximately 175 million gallons of wastewater per day. Engineering services included utility interconnection, 4.16kV power distribution design, pre-purchase specifications for the MCC transformer and soft starter, single line diagrams, control interconnection wiring schedules, grounding design, - [High BTU Plant Conversion from LFG to RNG](https://kupperengineering.com/project/high-btu-plant-conversion-from-lfg-to-rng/) - New Holland, PA We provided electrical engineering design services, including single line diagrams for all systems (medium and high voltage) of a 15kV service, 4.16kV for soft starters and large compressors, and below 600V for MCCs with VFDs and switchboards. Our team also provided a major electrical equipment layout plan, and a sample wire run - [Healthcare Brokerage Firm (2 Buildings)](https://kupperengineering.com/project/healthcare-brokerage-firm-2-buildings/) - For Building I (120,000 square feet), we performed the MEP construction documentation for multiple tenant improvement projects for this existing building. This project involved the following: New lighting layout and modification of HVAC, electrical distribution, lighting controls, and fire protection. It also included documentation for all back boxes of tele/data outlet locations and fire alarm - [Software Services Company Fit Out](https://kupperengineering.com/project/software-services-company-tenant-fit-out/) - We performed MEP design and construction documentation services for this tenant fit out project for a software company’s new headquarters (approx. 30,000 square feet). The space included two floors with an interior open staircase and open ceiling concept, and featured unique design elements, including a full game room with a pool table and shuffleboard, hammock - [Corporate Headquarters Fit Out](https://kupperengineering.com/project/corporate-headquarters/) - We provided MEP/FP design and construction administration services for a business analytics and solutions company’s 75,000 square foot corporate headquarters in Atlanta, Ga., and their 85,000 square foot office in Blue Bell, Pa. Our team also provided generator commissioning services at the Blue Bell location. - [Pharmaceutical Company Headquarters Fit Out](https://kupperengineering.com/project/pharmaceutical-company-headquarters-fit-out-2/) - We provided MEP design services and construction administration services for the top floor of this 20,000 square foot 4-story building. This included schematic design, design development, and construction documentation and permit drawings. Photo Credit: © Jeffrey Totaro, 2018. - [Pharmaceutical Company Fit Out](https://kupperengineering.com/project/pharmaceutical-company-fit-out/) - Our team provided engineering design services for a pharmaceutical company's 105,000 square foot space in Exton, Pa. This included utility coordination, circuiting and panel schedule details, lighting control systems for all receptacles and interior lighting fixtures, and emergency and egress lighting design. We also provided the fire alarm system design, and coordinated electrical requirements for - [26.4kV 10MW DC/AC Solar Farm Project](https://kupperengineering.com/project/26-4kv-10mw-dcac-solar-farm-project/) - Our team provided system integration services for a PJM FirstEnergy datalogger RTU at a solar facility. Services included configuration of a web-based virtual HMI in the datalogger, programming of the Data Station Plus, remote access setup, testing, onsite installation, startup and verification. - [21MW Natural Gas Distributed Power Generation Facility](https://kupperengineering.com/project/21mw-natural-gas-distributed-power-generation-facility/) - Initially, we performed the evaluation of a radio DTT system from four (4) remote substation and recloser locations at this natural gas generation facility. We then provided the following system integration services: Preliminary design for the radio DTT panel, antenna heights and mounting options per the SEL wireless path study, installation drawings of the panel - [Pharmaceutical Company Tier II Data Center](https://kupperengineering.com/project/pharmaceutical-companys-data-tier-ii-data-center/) - We provided one (1) Liebert CRV Air Cooled Precision Cooling System and one (1) Liebert 115 Ambient Direct Drive Air Cooled Condenser (ACC), as well as startup and testing. Demolition of the existing piping was necessary to accommodate the new installation. We performed the electrical installation of the new CRV and ACC in accordance with - [Cable TV Broadcasting Network Tier III Data Center Upgrade](https://kupperengineering.com/project/cable-tv-broadcasting-network-tier-iii-data-center-upgrade/) - Our client planned the construction for a new Technical Operations Center (TOC) as part of an expansion in one of their sectors. The TOC supports broadcasting equipment, including server and equipment racks that support their television show. Our MEP team coordinated with the broadcast designer for all physical, power, and cooling requirements, and designed the - [IT Solutions Company Tier III Data Center and HVAC Upgrade](https://kupperengineering.com/project/it-solutions-company-tier-iii-data-center-and-hvac-upgrade/) - This project involved a complete turnkey design and installation of four (4) new dual coil DX/CHW CRAC units to provide a redundant B side cooling solution to support the data center on a catastrophic failure of the chilled water system. It also included installation of a new equipment door to facilitate rigging of new CRAC - [450MW Hydroelectric Power Plant](https://kupperengineering.com/project/450mw-hydroelectric-power-plant-2/) - We provided system integration services for a utility RTU that included design, assembly, programming, and testing. We also provided coordination of data points, communication diagrams, RTU installation diagrams, onsite startup, and verification. For consistency in hardware within the site, the Allen Bradly ControlLogix PLC hardware was provided to concentrate all digital and analog signals. - [132MW Natural Gas Generation Project](https://kupperengineering.com/project/132mw-natural-gas-generation-project/) - We were contracted to perform engineering, testing, and commissioning of a power station’s outdoor 66kV switchyard. There were two (2) separate scopes to this work. The first part consisted of the addition of a new switchyard for the combustion turbine generator repowering of the plant. The second part consisted of modifications to the existing switchyard - [100MW Turbine Relay Replacement](https://kupperengineering.com/project/100mw-turbine-relay-replacement/) - We provided design of the electromechanical relay replacement 100MW black start diesel plant, including all AC and DC control schematics, and three line diagrams to house the new Beckwith and SEL differential relays. The existing differential relay replaced proved to be particularly challenging. We specified and procured the relays, FT-1s, and other components. The project - [69kV Industrial Plant Substation](https://kupperengineering.com/project/69kv-industrial-plant-substation/) - We designed a 69kV ringbus substation for an industrial plant that consisted of the following equipment and design: Two (2) 20MVA transformers, vertical break air switches with ground operators and interlocks, SF6 circuit breakers, aluminum rigid bus structure, structural supports, lightning protection, and grounding grid. The aluminum rigid bus structure was designed according to IEEE - [Hospital Fit Out Project (10,000 Square Feet)](https://kupperengineering.com/project/hospital-fit-out-project-10000-square-feet/) - This hospital purchased a new CT scanner and required professional MEP engineering, structural engineering, and architectural services for the renovation of the existing CT room to accept the new equipment. We provided the MEP design for the following systems: HVAC, normal power, emergency power, lighting, fire alarm, security/data/telephone (conduit system only), nurse call, sanitary and - [Biopharmaceutical Firm’s Laboratory Clean Room](https://kupperengineering.com/project/biopharmaceutical-firms-laboratory-clean-room/) - This project entailed demolishing and building walls and ceilings (including walkable ceiling) to enclose the equipment, leveling and sealing floors, supplying all utilities (480v/3 phase and 110v/ single phase power, plant steam, clean steam, WFI and USP water), relocating drain lines and tying into a double walled chemical waste line, relocating HEPA filters, performing standard ## Category - [Medium Voltage Substations and Relaying](https://kupperengineering.com/projects/medium-voltage-substations-and-relaying/) - [Solar, Wind, and Battery Storage](https://kupperengineering.com/projects/solar-wind-and-battery-storage/) - [Combined Heat and Power](https://kupperengineering.com/projects/combined-heat-and-power/) - [Landfill Gas, Biogas, and Renewable Natural Gas (RNG)](https://kupperengineering.com/projects/landfill-gas-biogas-and-natural-gas/) - [Control Panel Design and Build](https://kupperengineering.com/projects/control-panel-design-and-build/) - [SCADA and PLC Control Systems](https://kupperengineering.com/projects/scada-and-plc-control-systems/) - [Utility RTU and DTT](https://kupperengineering.com/projects/utility-rtu-and-dtt/) - [Utility Communications](https://kupperengineering.com/projects/utility-communications/) - [Commercial Buildings](https://kupperengineering.com/projects/commercial-buildings/) - [Arc Flash Hazard Analysis](https://kupperengineering.com/projects/arc-flash-hazard-analysis/) - [Mission Critical/Data Centers](https://kupperengineering.com/projects/mission-critical-data-centers/) - [Healthcare and Life Sciences](https://kupperengineering.com/projects/healthcare-and-pharmaceuticals/)